Abstract

Background and Purpose The Biometrics Flexible electrogoniometer has the potential to allow physiotherapists to record the motion of joints during dynamic functional activities. In order to make full and appropriate use of this device it is necessary to comprehend the design, attachment and measurement properties of this instrument. Methods The measurement properties of the Biometrics flexible electrogoniometer were investigated using a series of controlled experiments. The in vivo performance of the device was evaluated by comparing the results of the electrogoniometer to those from a TV motion analysis system while measuring knee movement during gait in five normal subjects. Results The results of these studies indicate that the electrogoniometers are stable, precise, accurate and repeatable in performance. Little variation exists between electrogoniometers or between the performance of an electrogoniometer at different times, on different days or in different environmental conditions. Small hysteretic effects and inaccuracies are present in the devices but these are of the order of 1 or 2 degrees. The system is not affected by environmental pollutants such as heat, electrical interference, convection currents or noise and therefore can be used in a variety of hospital settings. The device is however affected by abduction/adduction angle with angles of 40° or more giving substantial errors when associated with simultaneous flexion or extension. Conclusions The electrogoniometer should be attached firmly and securely across the joint in an essentially planar configuration. Provided care is taken to handle and mount the electrogoniometers appropriately they appear to record knee movement faithfully and accurately and the system is capable of giving valid and meaningful clinical data. The Biometrics Flexible electrogoniometer has the potential to allow physiotherapists to record the motion of joints during dynamic functional activities. In order to make full and appropriate use of this device it is necessary to comprehend the design, attachment and measurement properties of this instrument. The measurement properties of the Biometrics flexible electrogoniometer were investigated using a series of controlled experiments. The in vivo performance of the device was evaluated by comparing the results of the electrogoniometer to those from a TV motion analysis system while measuring knee movement during gait in five normal subjects. The results of these studies indicate that the electrogoniometers are stable, precise, accurate and repeatable in performance. Little variation exists between electrogoniometers or between the performance of an electrogoniometer at different times, on different days or in different environmental conditions. Small hysteretic effects and inaccuracies are present in the devices but these are of the order of 1 or 2 degrees. The system is not affected by environmental pollutants such as heat, electrical interference, convection currents or noise and therefore can be used in a variety of hospital settings. The device is however affected by abduction/adduction angle with angles of 40° or more giving substantial errors when associated with simultaneous flexion or extension. The electrogoniometer should be attached firmly and securely across the joint in an essentially planar configuration. Provided care is taken to handle and mount the electrogoniometers appropriately they appear to record knee movement faithfully and accurately and the system is capable of giving valid and meaningful clinical data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.