Abstract

This paper discusses the validity and limitations of the Tafel extrapolation method for the determination of corrosion rates for activation-controlled corrosion processes. Experimental corrosion rates determined by the Tafel method are compared with corrosion rates obtained by an independent chemical (i.e., non-electrochemical) method for iron in hydrochloric acid, iron in 3.5% NaCl, and for titanium in boiling 1 M sulfuric acid. The methods of confirmation of the corrosion rates involved colorimetric analysis of the dissolved cation or the use of an ion-implanted inert Xe marker. Additional examples taken from the literature involving other metals and other methods of validation are also discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.