Abstract

The Baveno VII consensus proposed criteria for the non-invasively diagnosis of clinically significant portal hypertension (CSPH) in patients with compensated advanced chronic liver disease (cACLD). The performance of Baveno VII criteria for assessing CSPH by two-dimensional shear wave elastography (2D-SWE) had not been well validated. We aimed to validate the performance of Baveno VII criteria for rule-in and rule-out CSPH by 2D-SWE. This is an international multicenter study including cACLD patients from China and Croatia with paired liver stiffness measurement (LSM), spleen stiffness measurement (SSM) by 2D-SWE, and hepatic venous pressure gradient (HVPG) were included. CSPH was defined as HVPG ≥ 10mmHg. A total of 146 patients with cACLD were enrolled, and finally 118 patients were included in the analysis. Among them, CSPH was documented in 79 (66.9%) patients. Applying the Baveno VII criteria for rule-out CSPH by 2D-SWE, [LSM ≤ 15kPa and platelet count ≥ 150 × 109/L] OR SSM < 21kPa, could exclude CSPH with sensitivity > 90% (93.5 or 98.7%) but negative predictive value < 90% (74.1 or 85.7%). Using the Baveno VII criteria for rule-in CSPH by 2D-SWE, LSM ≥ 25kPa OR SSM ≥ 50kPa, could diagnose CSPH with 100% specificity and 100% positive predictive values. Baveno VII criteria by 2D-SWE showed a good diagnostic performance for ruling in but not for ruling out CSPH, which might become an emerging non-invasive elastography tool to select the patients who needed non-selective beta blocker therapy.