Computerized methods promise quick, objective, and sensitive tools to quantify progression of radiological damage in rheumatoid arthritis (RA). Measurement of joint space width (JSW) in finger and wrist joints with these systems performed comparable to the Sharp-van der Heijde score (SHS). A next step toward clinical use, validation of precision and accuracy in hand joints with minimal damage, is described with a close scrutiny of sources of error. A recently developed system to measure metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints was validated in consecutive hand images of RA patients. To assess the impact of image acquisition, measurements on radiographs from a multicenter trial and from a recent prospective cohort in a single hospital were compared. Precision of the system was tested by comparing the joint space in mm in pairs of subsequent images with a short interval without progression of SHS. In case of incorrect measurements, the source of error was analyzed with a review by human experts. Accuracy was assessed by comparison with reported measurements with other systems. In the two series of radiographs, the system could automatically locate and measure 1003/1088 (92.2%) and 1143/1200 (95.3%) individual joints, respectively. In joints with a normal SHS, the average (SD) size of MCP joints was [Formula: see text] and [Formula: see text] in the two series of radiographs, and of PIP joints [Formula: see text] and [Formula: see text]. The difference in JSW between two serial radiographs with an interval of 6 to 12 months and unchanged SHS was [Formula: see text], indicating very good precision. Errors occurred more often in radiographs from the multicenter cohort than in a more recent series from a single hospital. Detailed analysis of the 55/1125 (4.9%) measurements that had a discrepant paired measurement revealed that variation in the process of image acquisition (exposure in 15% and repositioning in 57%) was a more frequent source of error than incorrect delineation by the software (25%). Various steps in the validation of an automated measurement system for JSW of MCP and PIP joints are described. The use of serial radiographs from different sources, with a short interval and limited damage, is helpful to detect sources of error. Image acquisition, in particular repositioning, is a dominant source of error.

Highlights

  • Joint space narrowing (JSN) and bone erosions are important outcome measures in rheumatoid arthritis (RA)

  • In the Dutch Rheumatoid Arthritis Monitoring (DREAM) dataset, the automated method failed in a single MCP joint due to abnormal positioning of the hand leaving 75 (99%) successfully measured pairs of digital radiographs (600 MCP and 600 proximal interphalangeal (PIP) joints) for analysis

  • Automated measurements of structural joint damage in RA has been a goal for several research groups

Read more

Summary

Introduction

Joint space narrowing (JSN) and bone erosions are important outcome measures in rheumatoid arthritis (RA). Radiological outcome is often expressed with the semiquantitative Sharp–van der Heijde-score (SHS).[1] This scoring system is not well suited to clinical practice or the analysis of large datasets, because it is time consuming and subject to inter- and intrascorer variability.[1] To overcome these limitations, computerized methods were proposed for the measurement of joint space width (JSW) of finger joints.[2,3,4,5,6,7] These systems promise elimination of subjective issues and a continuous measurement scale resulting in a higher sensitivity and improved reproducibility.[4,8,9,10,11,12,13,14]

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call