Abstract

Determination of bone age is routinely used for following up substitution therapy in congenital adrenal hyperplasia (CAH) but today is a procedure with significant subjectivity. The aim was to test the performance of automatic bone age rating by the BoneXpert software package in all radiographs of children with CAH seen at our clinic from 1975 to 2006. Eight hundred and ninety-two left-hand radiographs from 100 children aged 0 to 17years were presented to a human rater and BoneXpert for bone age rating. Images where ratings differed by more than 1.5years were each rerated by four human raters. Rerating was necessary in 20 images and the rerating result was closer to the BoneXpert result than to the original manual rating in 18/20 (90%). Bone age rating precision based on the smoothness of longitudinal curves comprising a total of 327 data triplets spanning less than 1.7years showed BoneXpert to be more precise (P<0.001). BoneXpert performs reliable bone age ratings in children with CAH.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.