Abstract

Biomechanical analyses using synchronized tools {electromyography (EMG), motion capture, force sensors, force platform, and digital camera] are classically performed in a laboratory environment that could influence the performance. We present a system for studying the running sprint start that synchronizes motion capture, EMG, and ground reaction force data. To maximize motion capture (Vicon 612 with six cameras), a special dim environment was created in the stadium. “Classical” tools were combined with “purpose-built” tools intended to analyse the different aspects of movement. For example, a synchronization system was built to create a common time-base for all data recordings and a portable EMG system was synchronized by a cable that was “disconnected” by the athlete's movement out of the blocks. This disconnection represented an independent event recorded by different tools. A “gap” was measured for some sprint start events between kinetic and kinematic (motion capture) data. Calibration results, measurements of time “gap”, and duration of the independent event were used to validate the accuracy of motion capture and the synchronization system. The results validate the entire experimental set-up and suggest adjustment values for motion capture data. This environment can be used to study other movements and can easily be applied to several sports.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call