A simple HPLC method with fluorescence detection of ciprofloxacin in human plasma was developed and validated. After protein precipitation, chromatographic separation of ciprofloxacin in plasma was achieved at 35 °C with a C18 column and acetonitrile–phosphate mixture, pH 3, as mobile phase. Quantitative determination was performed by fluorimetry after excitation at 278 nm. The method was specific and validated with a limit of quantification of 41 ng/ml. The intra- and inter-day coefficients of variation were between 0.5 and 6.6% and accuracy between −2.02 and 7.04%. Ciprofloxacin was stable in plasma for 40 days at −20 °C and after three freezing-thawing cycles. The method has been applied in a bioequivalence study of two formulation of 500 mg ciprofloxacin.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.