Abstract

Norberto, Matheus S., João Victor G. Torini, Matheus S. Firmino, and Marcelo Papoti. Validation of air storage system for hypoxia exposure during exercise. High Alt Med Biol. 00:000-000, 2024.-Considering the importance of optimizing normobaric hypoxia exposure (i.e., higher delivery capacity), the current study aims to validate a hypoxic air storage system. The study has a cross-over, one-blind randomized design. The air storage is composed of a piping system that directs hypoxic air from a hypoxia generator into nylon bags. Sixteen men (age, 25.4 ± 4.8 years; height, 174.9 ± 9.4 cm; weight, 77.1 ± 17.2 kg) performed three incremental treadmill tests until exhaustion on different days. For test-retest, the subjects repeated two tests in similar hypoxia conditions (H1 and H2; fraction of inspired O2 [FIO2] = ∼0.13; reliability analysis), and one time in normoxia (FIO2 = ∼0.20; condition comparison). Subjects' performance, blood lactate concentration ([La-]), arterial oxygen saturation (SpO2), oxygen consumption (VO2), heart rate (HR), and several respiratory-derived variables were evaluated. A comparison was made between the rest, moderate intensity, and exhaustion stages. All variables were compared using the Friedman test with Durbin-Conover post hoc (p < 0.05). The hypoxia test-retest showed no statistical differences for any variable. Time analysis showed similar behavior for SpO2, HR, and cardiorespiratory variables (p < 0.01) for both conditions. The mean FIO2 at rest and during the incremental treadmill test was higher for normoxia (20.6 ± 0.2%) than for H1 (13.8 ± 0.8%) and H2 (13.7 ± 0.3%) (p < 0.001). The VO2 response was higher in normoxia than during hypoxia exposure at moderate intensity (Normoxia = 43.1 ± 8.1; H1 = 38.7 ± 5.7; H2 = 35.8 ± 8.8 ml.kg-1.min-1) and at the exhaustion stage (Normoxia = 52.7 ± 12.5; H1 = 41.9 ± 8.8; H2 = 40.5 ± 8.9 ml.kg-1.min-1) (p < 0.01). SpO2 and HR showed excellent intraclass correlation coefficient (ICC) during all moments, whereas VO2, SpO2, ratio between ventilation and CO2 production (VE/VCO2), ratio between oxygen consumption and ventilation (VE/VO2), and HR showed moderate or good ICC and coefficient of variation <9% during hypoxia test-retest exercises. Thus, the air storage system showed validity for its application and reliability in the measurements associated.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call