Abstract

Miniaturized wearable Inertial Measurement Units (IMU) offer new opportunities for the functional assessment of motor functions for medicine, sport, and ergonomics. Sparse reliability validation studies have been conducted without a common specific approach and protocol. A set of guidelines to design validation protocol for these systems is proposed hereafter. They are based on the comparison between video analysis and the gold standard optoelectronic motion capture system for Gait Analysis (GA). A setup of the protocol has been applied to a wearable device implementing an inertial measurement unit and a dedicated harmonic oscillator kinematic model of the center of mass. In total, 10 healthy volunteers took part in the study, and four trials of walking at a self-selected speed and step length have been simultaneously recorded by the two systems, analyzed, and compared blindly (40 datasets). The model detects the steps and the foot which supports body weight. The stride time and the cadence have a mean absolute percentage error of 5.7% and 4.9%, respectively. The mean absolute percentage error in the measurement of step’s length and step’s speed is 5.6% and 13.5%, respectively. Results confirm that the proposed methodology is complete and effective. It is demonstrated that the developed wearable system allows for a reliable assessment of human gait spatio-temporal parameters. Therefore, the goal of this paper is threefold. The first goal is to present and define structured Protocol Design Guidelines, where the related setup is implemented for the validation of wearable IMU systems particularly dedicated to GA and gait monitoring. The second goal is to apply these Protocol Design Guidelines to a case study in order to verify their feasibility, user-friendliness, and efficacy. The third goal is the validation of our biomechanical kinematic model with the gold standard reference.

Highlights

  • Gait Analysis (GA) is one functional test used to determine the motor capability of subjects for clinical evaluation [1]

  • We considered the minimum number of steps for the trial equal to 8

  • One harmonic oscillator is associated with each step cycle; we look at the walking as a set of oscillators describing human kinematics

Read more

Summary

Introduction

Gait Analysis (GA) is one functional test used to determine the motor capability of subjects for clinical evaluation [1] It is currently carried out with advanced technologies including a multifactorial setup: an optoelectronic motion capture system for body kinematics collection, force platforms for ground reaction force measurement, and wireless electromyography (EMG) systems for recording the. It should be emphasized that on a treadmill, the subject’s walking cycle differs from the natural one, resulting in decreased stride length (4%) It increases the step cadence (6%) and this results in a shorter walking cycle and some variations for the decreased stance (7%) and the increased swing phases (5%). The subjects should be adequately trained for about 1 h to be confident to walk over the treadmill [5] prior to testing

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.