Abstract

Bone graft resorption following the Latarjet procedure has received considerable concern. Current methods quantifying bone graft resorption rely on two-dimensional (2D) CT-scans or three-dimensional (3D) techniques, which do not represent the whole graft volume/resorption (i.e., 2D assessment) or expose patients to additional radiation (i.e., 3D assessment) as this technique relies on early postoperative CT-scans. The aim of the present study was to develop and validate a patient-specific, CT-morphometric technique combining image registration with 3D CT-reconstruction to quantify bone graft resorption following the Latarjet procedure for recurrent anterior shoulder instability. Pre-operative and final follow-up CT-scans were segmented to digitally reconstruct 3D scapula geometries. A virtual Latarjet procedure was then conducted to model the timepoint-0 graft volume, which was compared with the final follow-up graft volume. Graft resorption at final follow-up was highly correlated to the 2D gold standard-technique by Zhu (Kendall tau coefficient = 0.73; p < 0.001). The new technique was also found to have excellent inter- and intra-rater reliability (ICC values, 0.931 and 0.991; both p < 0.001). The main finding of this study is that the technique presented is a valid and reliable method that provides the advantage of 3D-assessment of graft resorption at long-term follow-up without the need of an early postoperative CT-scan.