Abstract
To develop a simple and sensitive high-performance liquid chromatography (HPLC) assay with ultraviolet detection method of vandetanib in rat plasma. Samples were extracted with methanol and acetonitrile, evaporated, and then the residue was reconstituted in mobile phase. Vandetanib and the internal standard (I.S.) trazodone hydrochloride were separated with gradient elution (on a C18 Atlantis column using a mobile phase of acetonitrile/0.5% triethylamine, pH 3.0, with a flow rate of 1.0 ml/min), then detected at 341 nm. A linear curve over the concentration range of 80-4000 ng/ml (R² = 0.9998) was obtained. Intra- and inter-assay accuracy ranged from 98.80% to 103.08% and 95.32% to 98.40%, with high precision (R.S.D. % <5%), respectively. The mean absolute recovery was 96.65%. A simple and sensitive HPLC assay with ultraviolet detection method was developed for the determination of vandetanib in rat plasma. This method is sufficient for pharmacokinetic studies of vandetanib in small animals and may be applied to human pharmacokinetic studies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.