Abstract

Negative dietary cation-anion difference (DCAD) diets have been implemented to combat hypocalcemia, a common peripartal disease in dairy cows; however, the extent of compensatory metabolic acidosis necessary and the subsequent effects on performance are still debated. Additionally, there is a need for an inexpensive, accurate method to measure urine pH on farm during the prepartum period to assess the extent of metabolic acidosis achieved by negative DCAD diets. Therefore, this experiment was conducted to determine the accuracy of Fisher pH sticks (pHF; ThermoFisher Scientific) and pHion balance test strips (pHI; pHion Balance) compared with a portable pH meter (pHP; Accumet AP115, ThermoFisher Scientific) in measuring urine pH (UpH) and the effect of UpH on pre- and postpartum dry matter intake (DMI), milk, and milk composition yields. Cows consumed a total mixed ration with a DCAD of −118 mEq/kg for 4 wk prepartum and 397 mEq/kg for 4 wk postpartum. Prepartum UpH measurements (n = 75) for each cow were averaged and used to classify cows in terms of urine pH as low (UpH ≤5.54; mean ± standard deviation; 5.44 ± 0.07), medium (UpH >5.54 and ≤5.90; 5.67 ± 0.09), or high (UpH >5.90; 6.42 ± 0.36). Cows were milked twice a day, and milk samples were taken on d 7 ± 1.3, 14 ± 1.4, and 28 ± 1.1 relative to calving. Milk yield and DMI were recorded daily and averaged weekly. Bland-Altman plots and Lin's concordance correlation coefficient (CCC) were used to assess the agreement between pHP and pHF or pHI (n = 375). Receiver operating characteristic curves were used to determine the threshold with pHF and pHI that best discriminated between UpH >5.75 and ≤5.75 compared with pHP, and area under the curve (AUC) was used to assess the accuracy. At the UpH threshold of 5.75 for pHF and pHI, the sensitivity, specificity, and AUC were 89.5 and 87.4, 99.1 and 97.0, and 0.94 and 0.92, respectively. The CCC was 0.93 for pHF and pHI, indicating near-perfect agreement with pHP. The UpH did not affect pre- or postpartum DMI. There was a tendency for a UpH × week interaction for milk yield, in which milk yields were less for cows in the low and medium groups. In conclusion, pHI and pHF are accurate measurements for UpH, and UpH did not affect DMI; however, when UpH was low or medium, milk yield was decreased at wk 1 postpartum.

Highlights

  • Acidified diets prepartum are utilized in dairy cows to decrease the likelihood of hypocalcemia; the effect of the extent of acidification on cow performance is still debated

  • Our objective was to validate the accuracy of 2 pH strips to measure urine pH in dairy cows consuming an acidified diet prepartum and the association of urine pH with production performance

  • We determined that both pH strips are an accurate and affordable method to determine urine pH

Read more

Summary

Introduction

There is a need for an inexpensive, accurate method to measure urine pH on farm during the prepartum period to assess the extent of metabolic acidosis achieved by negative DCAD diets. This experiment was conducted to determine the accuracy of Fisher pH sticks (pHF; ThermoFisher Scientific) and pHion balance test strips (pHI; pHion Balance) compared with a portable pH meter (pHP; Accumet AP115, ThermoFisher Scientific) in measuring urine pH (UpH) and the effect of UpH on pre- and postpartum dry matter intake (DMI), milk, and milk composition yields.

Objectives
Results
Conclusion