Abstract
Respiratory-induced motions are prone to degrade the positron emission tomography (PET) signal with the consequent loss of image information and unreliable segmentations. This phantom study aims to assess the discrepancies relative to stationary PET segmentations, of widely used semi-automatic PET segmentation methods on heterogeneous target lesions influenced by motion during image acquisition. Three target lesions included dual F-18 Fluoro-deoxy-glucose (FDG) tracer concentrations as high- and low tracer activities relative to the background. Four different tracer concentration arrangements were segmented using three SUV threshold methods (Max40%, SUV40% and 2.5SUV) and a gradient based method (GradientSeg). Segmentations in static 3D-PET scans (PETsta) specified the reference conditions for the individual segmentation methods, target lesions and tracer concentrations. The motion included PET images followed a 4D-PET (PET4D) and a 3D-PET (PETmot) scan protocol. Moreover, motion-corrected PET images (PETdeb) were derived from the PETmot images. Segmentations in PET4D, PETmot and PETdeb were compared to the PETsta segmentations according to volume changes (ΔVol) and an error estimate (lowUptakeerror) for the lesion part covering the low tracer concentration. In PET4D images, all segmentation methods provided lowUptakeerror estimates equivalent to PETsta segmentations and, except for the Max40% segmentations, a slight volume expansion. In the PETmot images, the GradientSeg method results in an average 0.43 increased volume and an overestimation of 0.33 for the lowUptakeerror. The most accurate segmentations in PETmot, relative to PETsta, were accomplished by the 2.5SUV and SUV40% methods. In the PETdeb images, the GradientSeg method solitary provided segmentations equivalent to segmentation in PETsta images. The use of FDG with various tracer concentrations revealed, according to PETsta images, that the most constant segmentations for motion-corrected PET images (PET4D or PETdeb) were achieved using the GradientSeg method. In the absence of PET4D or PETdeb images, the 2.5SUV and SUV40% methods are most consistent to PETsta segmentations.
Highlights
Lung cancer is classified into two main categories, defined as small cell lung cancer (SCLC) and non-small cell lung cancer (NSCLC)
II. lowUptakeerror, a quantity metric quantifying the difference between the DSClowUptake in equation (5) and the DSClowUptake in the static PETsta image, relative to the DSClowUptake measured with equal tracer uptake in both high- and lowUptake sub-volumes, for the matching segmentation method and target
Apart from the Max40% segmentation method the PET4D scans produced enlarged segmented volumes compared to the PETsta scans with an increased ΔVol for the SUV40% of 2% (p = 0.001), gradientSeg of 4% (p = 0.03) and the 2.5SUV of 4% (p < 0.001), including all six positron emission tomography (PET) bins
Summary
Lung cancer is classified into two main categories, defined as small cell lung cancer (SCLC) and non-small cell lung cancer (NSCLC). The majority and minority of all lung cancers are classified as NSCLC (85%) and SCLC (15%) respectively [1]. For both SCLC and the NSCLC, radiotherapy is one treatment strategy depending of the extent of the cancer as indicated by lymph node involvement and potential metastases according to the TNM definition [2, 3]. The combined use of F-18 Fluoro-deoxy-glucose (FDG) PET and CT provide high accuracy for the clinical staging of lung cancers [6,7,8] and lower inter-observer variation for target definition [9]. Respiratory motion may result in motion artefacts, requiring motion encompassing images in PET/CT scans
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.