Abstract

The thyroid imaging reporting and data system (TIRADS) was proposed by experts for optimal ultrasound evaluation of malignancy risk of thyroid focal lesions. There are several versions of TIRADS, some of them have been validated sufficiently, and the others have not been well assessed. In this study, a recently launched Chinese version of TIRADS (C-TIRADS) for malignancy risk stratification of thyroid nodules was validated, and the performance was compared to that of the Korean TIRADS (K-TIRADS) and American College of Radiology(ACR) TIRADS (ACR-TIRADS). Archives of 2177 patients who had undergone thyroid ultrasound examination, coarse needle tissue biopsy and/or surgery were reviewed, and 1978 patients with 1982 thyroid nodules were assessed according to the three TIRADSs. The histopathology was taken as the golden standard. The results showed the 1982 thyroid nodules were consisted of 1306 benign nodules and 676 malignant nodules. The malignancy risk accounted for 1.09%, 2.14%, 10.34%, 49.28%, 88.19% and 85.29% of the total nodules that were categorised as C-TIRADS 2, 3, 4A, 4B, 4C and 5, respectively; 0.00%, 1.64%, 2.87%,18.71% and 82.22% of the total nodules that were categorised as ACR-TIRADS 1, 2, 3, 4 and 5, respectively; 0.85%, 3.27%, 24.27% and 80.96% of the total nodules that were categorised as K-TIRADS 2, 3, 4 and 5, respectively. The correlation between the category of TIRADS and percentile of malignancy was 0.94 in the C-TIRADS, 1.00 in the ACR-TIRADS, and 1.00 in the K-TIRADS, respectively. The highest values of accuracy(AUC) of ROC curves of C-TIRADS 4B, K-TIRADS 5 and ACR-TIRADS 5 were taken as the cut-off values for risk stratification, respectively. The sensitivity, specificity, positive and negative predictive values and AUC by C-TIRADS 4B, K-TIRADS 5 and ACR-TIRADS 5 for malignancy risk stratification of thyroid nodules were 90.83%, 84.23%, 74.88% and 94.66% and 0.88, respectively; 83.58%, 89.82%, 80.95%, 91.36% and 0.87, respectively; and 85.50%, 90.35%, 82.10%, 92.33% and 0.88, respectively (P>0.05 for all). We concluded that the C-TIRADS has excellent performance in the malignancy risk stratification of thyroid nodules by the optimized cut-off value, which is comparable to that in K-TIRADS and ACR-TIRADS.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.