Abstract
A simple, specific, accurate and precise high performance thin layer chromatography method has been developed for the estimation of paroxetine hydrochloride in tablet dosage forms. The quantification was carried out at 296 nm. Developed method was validated in terms of linearity, accuracy, precision, repeatability and specificity. Limit of detection and limit of quantification of paroxetine hydrochloride were found to be 60 ng/spot and 160 ng/spot, respectively. The linearity range for paroxetine hydrochloride was found to be 160-960 ng/spot with correlation coefficient of 0.995. Content of paroxetine hydrochloride in two tablet dosage forms was found to be 100.10 and 100.20%, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.