Abstract

The author introduces an organic solvent-free, small-scale, time shortening, economical procedure for quantitation of oxytetracycline (OTC) and its 4-epimer, 4-epi-oxytetracycline (4eOTC), in cow’s milk. Sample preparation was performed by homogenization using a handheld ultrasonic-homogenizer with water followed by Mono Tip® C18 pipette tip contains silica monolith bonded with octadecyl group with water eluent. The HPLC separation was achieved a C4 column with an isocratic aqueous mobile phase and a photodiode array detector (PDAD). The total time required for the analysis of one sample was less than 6 min. The method validation data were well within the international analytical method acceptance criteria. The limits of quantitation for OTC and 4eOTC were 0.035 and 0.048 μg/mL, respectively. The present technique may be proposed as an international standardized analytical method for routine residue monitoring for OTC and 4eOTC in milk.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.