Abstract

In this study, a method for the quantitation of SK5474 in rat plasma was developed and validated using high performance liquid chromatography (HPLC). The plasma samples were prepared by deproteinization, and sildenafil was used as an internal standard. Chromatographic separation was achieved using a reversed-phase (C18) column. The mobile phase, 0.02M ammonium acetate buffer:acetonitrile (48:52, v/v), was run at a flow rate of 1.0mL/min, and the column eluent was monitored using an ultraviolet detector at 254nm at room temperature. The retention times of sildenafil and SK5474 were approximately 5.8 and 7.2min, respectively. The quantitation limit of SK5474 in rat plasma was 0.03μg/mL. Pharmacokinetic parameters of SK5474 was evaluated after intravenous (i.v.; at doses of 15mg/kg) and oral (p.o.; at doses of 30mg/kg) administration of SK5474 in rats. After p.o. administration (30mg/kg) of SK5474, F (fraction absorbed) value was approximately 46.0%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.