Abstract

As a part of ARIES-ACT research, we have been performing a detailed re-examination of requirements and design of vacuum vessels for fusion power plants. This paper discusses structural analysis performed in support of this examination. We have performed parametric 3-dimensional finite element analyses of ARIES-ACT-type vacuum vessels. The vacuum vessel structure is subjected to different types of loads such as atmospheric pressure, weight of the vessel itself and off-normal loads such as over-pressurization due to a leak in fusion core components, electromagnetic forces from disruptions, etc. Ribbed structure is considered in order to minimize the thickness of the vacuum vessel as well as to cool the system. We will discuss our results including structural response to various loads and trade-offs among structural design choices.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.