Abstract
A previously identified difficulty with the development of latent fingerprints on low-density polyethylene (LDPE) by vacuum metal deposition (VMD) is that excess gold deposition prevents effective zinc deposition and so inhibits latent print development [1]. The investigation of a means to correct for excess gold deposition was the basis for this study. Exposure to zinc and the readmission of air into the vacuum chamber followed by VMD development results in the deactivation of the initial gold clusters due to the formation of zinc oxide and the adsorption of air and water molecules. As a result, the majority of the gold deposited during the second treatment creates new gold clusters rather than adding to the gold clusters previously formed. After excess gold deposition on LDPE, the deposition of 1.5 times the optimum gold amount will result in good-quality normal development. The results also indicate that, on all surfaces, at least twice the initial gold count should be used for re-treatment when further development is required after air has been readmitted to the chamber.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.