Abstract

Staphylococcus aureus is a leading cause of ventricular assist device-related infections. This study evaluated the protective effect against S. aureus infection of active and passive immunization that targeted 3 proteins involved in bacterial attachment to a murine intra-aortic polyurethane patch. Active immunization of mice with a combination of the A domains of clumping factor A (ClfA), fibronectin-binding protein A (FnBPA) and fibronectin-binding protein B or passive immunization with monoclonal antibodies against ClfA and FnBPA resulted in a higher level of protection than that obtained by vaccination with either protein or antibody alone. The combination of antibodies or protein antigens appears to provide enhanced protection against prosthetic-device infection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.