Abstract

You have accessJournal of UrologyCME1 Apr 2023V12-01 VISUALIZATION OF IDIOPATHIC LEAD MIGRATION RESULTING IN SNM DEVICE FAILURE Nicholas Koch, Kayla Graham, Samuel Ivan, Heather Winn, Ryan Darvish, and Michael Kennelly Nicholas KochNicholas Koch More articles by this author , Kayla GrahamKayla Graham More articles by this author , Samuel IvanSamuel Ivan More articles by this author , Heather WinnHeather Winn More articles by this author , Ryan DarvishRyan Darvish More articles by this author , and Michael KennellyMichael Kennelly More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000003347.01AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Twiddler’s syndrome is a well described phenomenon in cardiac literature where manipulation of pacemaker and implantable cardioverter-defibrillator (ICD) batteries results in twisting of the lead, ultimately causing knotting , fracture and/or malfunction. Twiddler’s syndrome is also identified in neuromodulation devices, though poorly studied and understood in urologic literature surrounding sacral neuromodulation (SNM). After a patient’s premature failure of a SNM device with twisted leads, we sought to identify the underlying etiology. METHODS: One patient experienced two SNM device failures within 5 months due to lead migration and extreme twisting. This video outlines our investigation into the patient's underlying etiology Twiddler’s syndrome, previously published instances of the phenomenon in cardiology and sacral neuromodulation, a discussion of risk factors, and a finding of spontaneous Twiddler’ syndrome captured via fluoroscopy and office examination on video, with realtime visualization of patients IPG flipping within it's pocket. RESULTS: After in office physical examination and fluoroscopic investigation captured live on video, she was found to have a mobile and easily manipulated battery with observed and recorded flipping of her battery associated with everyday behaviors, including dressing. CONCLUSIONS: Neuromodulator lead migration and malfunction can occur due to Twiddler’s syndrome, often associated with the intentional manipulation of the lead by patients, commonly with psychiatric diagnoses. However, our video demonstrates via physical exam and fluoroscopy an instance of unintentional manipulation likely due to device location, patient habitus and pocket size. Considering these findings, the evaluation of a patient’s body habitus for location of placement, as well as use of additional safety measures including limiting pocket size, anchoring of the device ± use of TYVK pouch, are important considerations for surgical planning that may aid in prevention of idiopathic Twiddler’s syndrome and premature device failure. Source of Funding: N/A © 2023 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 209Issue Supplement 4April 2023Page: e1065 Advertisement Copyright & Permissions© 2023 by American Urological Association Education and Research, Inc.MetricsAuthor Information Nicholas Koch More articles by this author Kayla Graham More articles by this author Samuel Ivan More articles by this author Heather Winn More articles by this author Ryan Darvish More articles by this author Michael Kennelly More articles by this author Expand All Advertisement PDF downloadLoading ...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.