Abstract

You have accessJournal of UrologyCME1 May 2022V09-11 NOVEL USE OF THE DAVINCI SINGLE PORT ROBOT IN NEPHROURETERECTOMY OF A HORSESHOE KIDNEY John Sheng, Chrystal Chang, Michael Stifelman, and Mutahar Ahmed John ShengJohn Sheng More articles by this author , Chrystal ChangChrystal Chang More articles by this author , Michael StifelmanMichael Stifelman More articles by this author , and Mutahar AhmedMutahar Ahmed More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000002617.11AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Performing a robotic-assisted laparoscopic nephroureterectomy can be challenging, especially during the distal ureterectomy and bladder cuff portion. We demonstrate how the Da Vinci Single Port Robot facilitates certain portions of the case. We show how the procedure can be performed with one incision compared to a multiport robotic or open technique. METHODS: A 73 year old male was diagnosed with a high grade urothelial cancer of the right renal pelvis on ureteroscopic biopsy. He then underwent neoadjuvant chemotherapy. He also has a horseshoe kidney, making the case more complex than a regular nephroureterectomy. Patient underwent single port robotic assisted laparoscopic right nephroureterectomy with bladder cuff. RESULTS: A single 25mm incision was made supraumbilically for the robotic instruments. No assistant port was used, making this a true single port procedure. The remotely operated suction irrigation system (ROSI) was used not only for suction but dissection as well. The operative time for the case was 187 minutes. Estimated blood loss was 150cc. The patient was discharged within 18 hours of surgery with a foley catheter and no need for post op narcotic use. Even though there is limited space underneath the liver, we were able to work underneath the liver without the use of a liver retractor by using the elbow of our 4th arm to hold it up. We use the “Relocate” function of the SP Robot to perform our distal ureterectomy and bladder cuff portion, preventing the need to re-dock the robot. We performed multiple procedures with one incision: partial nephrectomy, distal ureterectomy with bladder cuff and lymphadenectomy. At our institution, we have performed seven robotic single port nephroureterectomies. Average operating time is 126 minutes, estimated blood loss 92cc and average length of stay is 1.8 days. CONCLUSIONS: The use of the Da Vinci Single Port robot can make increasingly complex cases even more minimally invasive. This can reduce post-operative pain, improve cosmesis and shorten hospital stay. However there is a learning curve in the use of the Da Vinci SP robot. We hope to improve our techniques and surgical approaches further to keep our procedures as minimally invasive as possible. Source of Funding: None © 2022 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 207Issue Supplement 5May 2022Page: e808 Advertisement Copyright & Permissions© 2022 by American Urological Association Education and Research, Inc.MetricsAuthor Information John Sheng More articles by this author Chrystal Chang More articles by this author Michael Stifelman More articles by this author Mutahar Ahmed More articles by this author Expand All Advertisement PDF DownloadLoading ...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.