Abstract
You have accessJournal of UrologyAdrenal & Renal Oncology I (Nephron Sparing Surgery) (V04)1 Sep 2021V04-06 3D AUGMENTED REALITY ROBOT ASSISTED PARTIAL NEPHRECTOMY GUIDED BY INDOCYANINE GREEN: A STEP NEARER TO “AUTOMATIC” OVERLAPPING? Francesco Porpiglia, Daniele Amparore, Federico Piramide, Enrico Checcucci, Paolo Verri, Gabriele Volpi, Sabrina De Cillis, Alberto Piana, Pietro Piazzolla, Andrea Bellin, Matteo Manfredi, Vezzetti Enrico, and Cristian Fiori Francesco PorpigliaFrancesco Porpiglia More articles by this author , Daniele AmparoreDaniele Amparore More articles by this author , Federico PiramideFederico Piramide More articles by this author , Enrico CheccucciEnrico Checcucci More articles by this author , Paolo VerriPaolo Verri More articles by this author , Gabriele VolpiGabriele Volpi More articles by this author , Sabrina De CillisSabrina De Cillis More articles by this author , Alberto PianaAlberto Piana More articles by this author , Pietro PiazzollaPietro Piazzolla More articles by this author , Andrea BellinAndrea Bellin More articles by this author , Matteo ManfrediMatteo Manfredi More articles by this author , Vezzetti EnricoVezzetti Enrico More articles by this author , and Cristian FioriCristian Fiori More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000002000.06AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: In the actual scenario of nephron sparing “precision” surgery, the availability of hyper-accuracy 3D models (HA3DTM) revealed to be useful thanks to their spatial visualization. In the last years, a step further was represented by the advent of Augmented Reality (AR) technology, in which the superimposition of 3D virtual images allowed an intraoperative surgical navigation. In this study, with the aim to automatize the 3D virtual and endoscopic images co-registration, we developed a dedicated software based on computer vision algorithms. METHODS: This is a feasibility study of our new dedicated software, named “IGNITE” (Indocyanine GreeN automatIc augmenTed rEality), able to automatically anchor the HA3DTM model with the endoscopic vision of the real organ. For this project we applied computer vision algorithms which need clear landmarks to correctly identify the target organ. In order to overcome the colors similarity of the operative field and to provide a more depictable shape for the software we decided to use indocyanine. In order to overcome the colors similarity of the operative field and to provide a more depictable shape for the software we decided to use indocyanine. In this way the kidney appears as a bright green organ surrounded by a dark operative field. We enrolled patients with renal mass scheduled for AR robot-assisted partial nephrectomy. All patients underwent a four-phase contrast-enhanced CT, in order to create the HA3D models, visualized as AR images inside the robotic console.Perioperative and postoperative data were collected and analyzed. RESULTS: Ten cases were enrolled in this pilot experience. Mean lesions size was 46.6 (+16.3) mm. Median PADUA score was 9 (IQR 8-10). Mean operative and ischemia time were 88.9 (+42.7) and 20.5 (3.5) min, respectively. In all the cases (even in completely endophytic or posterior tumors) the automatic tracking was successful without manual assistance by the operator, allowing to perform enucleoresection of the renal mass with no damages of the tumor’s pseudocapsule and avoiding positive surgical margins. Moreover, no intra- or postoperative complications (>2 according to Clavien- Dindo) were recorded. CONCLUSIONS: Present findings suggest that the new evolution of our AR platform based on computer vision algorithm allows an effective automatic AR RAPN. The automatic 3D model overlapping lead to a correct identification of the tumor, even in endophytic and posterior cases, without risk of complications or positive surgical margins. Source of Funding: N/a © 2021 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 206Issue Supplement 3September 2021Page: e292-e293 Advertisement Copyright & Permissions© 2021 by American Urological Association Education and Research, Inc.MetricsAuthor Information Francesco Porpiglia More articles by this author Daniele Amparore More articles by this author Federico Piramide More articles by this author Enrico Checcucci More articles by this author Paolo Verri More articles by this author Gabriele Volpi More articles by this author Sabrina De Cillis More articles by this author Alberto Piana More articles by this author Pietro Piazzolla More articles by this author Andrea Bellin More articles by this author Matteo Manfredi More articles by this author Vezzetti Enrico More articles by this author Cristian Fiori More articles by this author Expand All Advertisement Loading ...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.