Tritium contamination on surfaces is often encountered during operation and maintenance of equipment at the Darlington Tritium Removal Facility and likely at other tritium handling facilities. The use of efficient decontamination techniques that produce little or no secondary wastes is desirable. At Ontario Hydro Technologies (OHT) we have been developing a process utilizing a combination of ultraviolet (UV) radiation and ozone gas to remove tritium surface contamination from materials often used in tritium service. This paper summarizes the performance of the technique. The results are encouraging because the technique is very effective, simple in terms of equipment requirements and concentrates tritium in an easily managed waste form. 7 refs., 3 figs., 2 tabs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.