Abstract

We report on a study focusing on UV exposure conditions in three different types of chambers used for accelerated ageing of materials. The first chamber is equipped with four 300-W UVA/UVB mercury vapour lamps (Ultra-Vitalux/Osram). The second chamber uses four 40-W UVA fluorescent lamps (QUV-340/Q-Lab). The third chamber is Weather-Ometer Ci3000+ from Atlas with a 4500-W xenon arc lamp. UV irradiance prevailing in each chamber was measured using Bentham DM150 double monochromator spectroradiometer. The results were compared to measurements of solar spectral UV irradiance at Jokioinen, Finland, with a Brewer MkIII double monochromator spectrophotometer. The spectral shapes of the exposing UV radiation in the different chambers were found to notably differ from each other and from the solar UV spectrum. Both spatial inhomogeneities and temporal variability caused by various factors, like the ageing of the lamps, were detected. The effects were found to strongly depend on wavelength of the exposing UV radia...