Abstract
The stability of prestressed cable trusses subjected to static and dynamic loads is analysed in the paper. The stiffness of the elastic cable truss system was varied by changing the prestressing force. Modelling results for different levels of tension show that, in terms of satisfying dynamic resistance conditions, a much greater tensile force is required for cable grids with diagonal members, compared to those with vertical rods. The conclusions derived constitute recommendations for the use of calculation methods, as well as for the determination of prestressing forces under which stability criteria are fulfilled.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Croatian Association of Civil Engineers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.