Abstract

Background: To investigate the utilization of PET-CT in target volume delineation for three-dimensional conformal radiotherapy in patients with non-small cell lung cancer (NSCLC) and atelectasis.
 Methods: Thirty NSCLC patients who underwent radical radiotherapy from August 2010 to March 2012 were included in this study. All patients were pathologically confirmed to have atelectasis by imaging examination. PET-CT scanning was performed in these patients. According to the PET-CT scan results, the gross tumor volume (GTV) and organs at risk (OARs, including the lungs, heart, esophagus and spinal cord) were delineated separately both on CT and PET-CT images. The clinical target volume (CTV) was defined as the GTV plus a margin of 6-8 mm, and the planning target volume (PTV) as the GTV plus a margin of 10-15 mm. An experienced physician was responsible for designing treatment plans PlanCT and PlanPET-CT on CT image sets. 95% of the PTV was encompassed by the 90% isodose curve, and the two treatment plans kept the same beam direction, beam number, gantry angle, and position of the multi-leaf collimator as much as possible. The GTV was compared using a target delineation system, and doses distributions to OARs were compared on the basis of dose-volume histogram (DVH) parameters.
 Results: The GTVCT and GTVPET-CT had varying degrees of change in all 30 patients, and the changes in the GTVCT and GTVPET-CT exceeded 25% in 12 (40%) patients. The GTVPET-CT decreased in varying degrees compared to the GTVCT in 22 patients. Their median GTVPET-CT and median GTVPET-CT were 111.4 cm3 (range, 37.8 cm3-188.7 cm3) and 155.1 cm3 (range, 76.2 cm3-301.0 cm3), respectively, and the former was 43.7 cm3 (28.2%) less than the latter. The GTVPET-CT increased in varying degrees compared to the GTVCT in 8 patients. Their median GTVPET-CT and median GTVPET-CT were 144.7 cm3 (range, 125.4 cm3-178.7 cm3) and 125.8 cm3 (range, 105.6 cm3-153.5 cm3), respectively, and the former was 18.9 cm3 (15.0%) greater than the latter. Compared to PlanCT parameters, PlanPET-CT parameters showed varying degrees of changes. The changes in lung V20, V30, esophageal V50 and V55 were statistically significant (Ps< 0.05 for all), while the differences in mean lung dose, lung V5, V10, V15, heart V30, mean esophageal dose, esophagus Dmax, and spinal cord Dmax were not significant (Ps> 0.05 for all).
 Conclusions: PET-CT allows a better distinction between the collapsed lung tissue and tumor tissue, improving the accuracy of radiotherapy target delineation, and reducing radiation damage to the surrounding OARs in NSCLC patients with atelectasis.

Highlights

  • To investigate the utilization of PET-Computed Tomography (CT) in target volume delineation for three-dimensional conformal radiotherapy in patients with non-small cell lung cancer (NSCLC) and atelectasis

  • When NSCLC patients have atelectasis or obstructive pneumonia, it is difficult to distinguish the boundaries between incompletely expanded lung tissue and tumor tissue by conventional CT, which often results in inaccurate target delineation

  • It was difficult to distinguish the boundaries between incompletely expanded lung tissue and tumor tissue by conventional CT, which resulted in excessive target delineation

Read more

Summary

Introduction

To investigate the utilization of PET-CT in target volume delineation for three-dimensional conformal radiotherapy in patients with non-small cell lung cancer (NSCLC) and atelectasis. Most of the radiation treatment planning system is based on Computed Tomography (CT) image as a target area sketching and dose calculation basis. When NSCLC patients have atelectasis or obstructive pneumonia, it is difficult to distinguish the boundaries between incompletely expanded lung tissue and tumor tissue by conventional CT, which often results in inaccurate target delineation. PET-CT can effectively identify the boundary between atelectasis region and lung cancer, make radiation target area precision, avoid unnecessary radiation injury and reduce radiation complications, thereby improving the radiation effect. PET-CT can make target area sketch more accurate, better protect surrounding normal tissues, enhance the curative effect and reduce the radiation complications, thereby improving the patient's quality of life (Tables 1, 2 and 3)

Methods
Results
Discussion
Conclusion