Abstract

BackgroundThe objective of the current study was to summarize and evaluate all published evidence regarding viscoelastic testing in the field of liver surgery. MethodsA systematic search of the literature was performed using Medline/PubMed, Scopus, Cochrane Library Central, Google Scholar, and clinicaltrials.gov databases. The following keywords were used:“Thromboelastography”, “Thromboelastometry”, “Viscoelastic tests OR testing”, “Sonoclot Devices”, “Point-of-care tests OR testing”, “Coagulation OR Haemostasis OR Hemostasis”, “Liver OR Hepatic Surgery”, “Cirrhosis.” ResultsA total of 12 studies analyzing 348 patients who underwent viscoelastic testing of coagulation during liver surgery for benign or malignant diseases were included; 7 (58.3%) studies reported on the use of thromboelastography (TEG), and 5 (41.7%) reported on rotational thromboelastometry (ROTEM). Viscoelastic testing (TEG and ROTEM) identified normo-, hyper- and hypo-coagulable status in 77% (n = 268/348), 18.4% (n = 64/348), and 4.6% (n = 16/348) of patients, respectively. In contrast, conventional coagulation tests indicated normo-coagulability in 111 patients (34.2% out of 325) and hypo-coagulability in 214 (65.8% out of 325) patients following liver resection. No patient (0% out of 291) experienced postoperative hemorrhage, whereas 5.8% (n = 17/291) experienced postoperative thromboembolic events. ConclusionsGlobal viscoelastic testing may be a reasonable adjunct to conventional coagulation testing to provide a more robust assessment of the coagulation status of patients undergoing liver surgery.