Abstract

Forty-seven patients (67 wrists) with a clinical and electrophysiological diagnosis of CTS, and 20 healthy controls (40 wrists) were enrolled. Median nerve ultrasound (US) was performed at the carpal tunnel inlet to measure the cross-sectional area (CSA) and vessel score. Power Doppler sonograms from nerves with detectable INBF were processed with PixelFlux to obtain the maximum perfusion intensity (MPI). Forty-nine percent of CTS patients had detectable INBF compared with none in the control group (P < 0.0001). MPI correlated significantly with vessel score (r = 0.945, P < 0.0001), CSA (r = 0.613, P < 0.0001), and electrophysiological severity (r = 0.440, P < 0.0001). MPI had higher intra- or interobserver reliability compared with vessel score (0.95 vs. 0.47). MPI is a better method for quantification of INBF. Muscle Nerve, 2016 Muscle Nerve 55: 77-83, 2017.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.