Abstract

Carbon dioxide is produced in the tissues as a byproduct of aerobic metabolism, then transported to the lungs by the venous circulation and is finally eliminated during the expiratory phase of ventilation. End-tidal CO2(ETCO2) is defined as the peak CO2 value during expiration and is dependent on adequate pulmonary blood flow to the ventilating areas of the lung. ETCO2 in healthy subjects differs normally by <5 mmHg from the arterial CO2(PaCO2). An increased ETCO2-PaCO2 gap can be found in association with a decreased pulmonary blood flow and/or increased dead-space. Capnometry is the measurement of CO2 concentration of tidal gas at the airway opening. Capnography is the graphic display of the measured CO2. Capnography is an important non-invasive technique that can monitor CO2 production, pulmonary perfusion and alveolar ventilation as well as respiratory patterns.[1] Capnography has been shown to be effective as a tool for early detection of complications during anesthesia including, hypoventilation, esophageal intubation and circuit disconnection. Tinker et al.[2] concluded after a closed claim analysis for the American Society of Anesthesiology that the application of capnography and pulse oximetry together could have helped prevent 93% of avoidable anesthesia mishaps identified in their study. Capnometry is now a standard of care during administration of general anesthesia, for confirmation of placement of endotracheal tube after intubation and during transportation of an intubated patient. It has been increasingly used in intubated ventilated patients in intensive care units to safely wean patients, decrease the number of arterial blood gases, detect endotracheal displacement and prevent hypercarbia. Nasal ETCO2 monitoring is useful during procedural sedation and post-operative monitoring in the recovery room. In addition, volumetric capnography can be used as a non-invasive method to measure cardiac output. In this journal, Mehta and colleagues presented their data showing good correlation between ETCO2 and PaCO2 in neonates and children.[3] As expected correlation between ETCO2 and PaCO2 was weaker when P/F ratio was 200. Although, the mean bias with the Bland-Altman plot was low in neonates as well as children the limits of agreement is large suggesting variability of PaCO2-ETCO2 gap in their sample. Their findings confirm previously published data in neonates. The gradient between PaCO2 and ETCO2 depends upon the amount of dead space during ventilation.[4] Many variables influence the percentage of dead space to total minute ventilation. Decreased pulmonary blood flow, pulmonary disease or hyperinflation of lungs can lead to increased dead space and consequently high PaCO2-ETCO2 gap. An important limitation of using ETCO2 as a surrogate for PaCO2 measurement is that the PaCO2-ETCO2 gap changes from patient to patient based on underlying pulmonary and cardiovascular conditions and ventilation strategies and within the same patient with significant changes in the cardiopulmonary condition. In a stable patient ETCO2 monitoring can be used as trending tool during weaning or after the change in ventilator setting. Periodic measurement of PaCO2 is necessary to make sure the PaCO2-ETCO2 gap is not significantly altered. Mehta et al.[3] confirmed previous reports of ETCO2 monitoring as a valid tool in sick, mechanically ventilated neonates and children. In addition to monitoring ventilation status, continuous ETCO2 is useful in early detection of dislodgement of endotracheal tube. Waveform of capnography may be useful in detecting certain type of pulmonary pathology, such as obstructive airway disease. ETCO2 monitoring is a valuable tool during cardiopulmonary resuscitation (CPR). ETCO2 levels fall to low levels at the onset of cardiac arrest, increases with effective CPR and returns to normal levels at return of spontaneous circulation. Although there are no absolute contraindications of use of ETCO2 monitoring there few limitations for its use.[5] Large main stream capnometers can add dead space and may cause kinking of endotracheal tubes. Fortunately, most modern capnometers add a small amount dead space and are of light weight. Gas sampling rate from a side stream capnometer can lead to auto triggering and sometimes inadequate tidal volume delivery in very small neonates. Secretions and condensation in the tubing and leaks in the ventilator circuit can affect the accuracy of ETCO2. End-tidal carbon dioxide monitoring is a useful tool in the management of acutely ill and is becoming a standard of care in many clinical situations. In ventilated patients, ETCO2 monitoring is best used as a trending device for ventilation in addition to detecting endotracheal position.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.