Abstract
Flow cytometry immunophenotyping is limited by poor resolution of T-cell clones. A newly described antibody was recently used to distinguish normal peripheral blood T cells from malignant T-cell clones. Here, we evaluate this antibody as a new diagnostic tool for detecting T-cell clonality in mature peripheral T-cell lymphomas. Immunostaining for the T-cell receptor β chain constant region 1 (TRBC1) along with routine T-cell markers was performed on 51 peripheral blood and two bone marrow samples submitted to the flow cytometry laboratory for suspected T-cell malignancy. TRBC immunophenotyping identified malignant T-cell clones with 97% sensitivity and 91% specificity. Findings correlated with molecular T-cell clonality testing. In cases with equivocal molecular results, TRBC1 immunophenotyping provided additional diagnostic information. TRBC1 flow cytometric immunophenotyping is a robust and inexpensive method for identifying T-cell clonality that could easily be incorporated into routine flow cytometric practice.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.