Abstract

The increased reliability and ultimately reduced life cycle cost of high and premium efficiency three phase motors in a process control application is discussed. The reduced energy consumption of these motors is evaluated in a public water system case study under variable frequency conditions. The importance of the consideration of a combined system, which includes variable speed control, motor and load — as opposed to only replacing with high efficiency motors for energy saving purposes — is practically observed and reported on. The paper reports on the marginal improvement in energy consumption at reduced supply frequency for motor replacement only (not surprising) but a very impressive 46% saving in energy consumption by controlling pumped water at a reduced but constant delivery rate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.