Abstract

Recovery of heat from electrolysers is potentially interesting to increase the total system efficiency, reduce CO2 emissions, and increase the economic feasibility of both hydrogen and heat production. This study examines different designs for the utilisation of (waste) heat from a 2.5 MWel polymer electrolyte membrane (PEM) electrolyser. Redundancy is important in the design, to ensure safe operation regardless of the heat demand of the heat consumer. We analysed cases with local heat consumption (with/without a heat pump) and coupling with a district heating network (DHN). Overall, 14–15% of the electricity input to the stack can be utilised by a heat consumer, increasing the total system efficiency to 90% (HHV) with CO2-savings of 0.08 (DHN)-0.28 (direct use) tonne CO2/MWhheat, used. We performed a first-order techno-economic analysis showing that the levelized costs of the electrolyser heat (8.4–36.9 €/MWh) fall within the range of other industrial heat sources and below lower-temperature heat sources.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.