Abstract

Dentists make use of orthodontic wires such as SS 18/8, SS 316, Ni-Cr etc., to regulate the growth of teeth. In the saliva environment these wires undergo corrosion. Aside from this, they undergo corrosion by the food items, juices and Tablets orally in taken. Corrosion resistance of SS 18/8 alloy in artificial saliva (AS) , in the absence and presence of Digene Tablet juice, has been investigated by polarization and AC impendance techniques. It is inferred that corrosion resistance of SS 18/8 alloy in artificial saliva decreases in presence of Digene Tablet. This is exposed by decrease in Linear Polarization Resistance (LPR) value, Charge transfer resistance (Rt) value, in impedance value, and increase in corrosion current and double layer capacitance value(Cdl). In presence of Digene Tablet, the LPR value decreases from 3488228 to 1629535 Ohmcm2. The corrosion current value increases from 1.447 x10-8 to 2.637x10-8A/cm2 . The Charge transfer resistance (Rt) value decreases from 37796 to 10481Ohmcm2 . The double layer capacitance value increases from 1.349x10-10 F/cm2 to 4.866x10-10F/cm2. The impedance value decreases from 4.857 to 4.428. Hence it implies that people with orthodontic wire made of SS 18/8 alloy should avoid taking Digene Tablet juice orally.

Highlights

  • It is interesting to note that for some people the arrangement of teeth are not in a regular manner by God’s greatness

  • Corrosion resistance of SS 18/8 alloy in artificial saliva decreases in presence of Digene

  • Corrosion resistance of SS 18/8 alloy in artificial saliva (AS), in the absence and presence of Digene Tablet has been investigated by polarization and AC impedance techniques

Read more

Summary

Introduction

It is interesting to note that for some people the arrangement of teeth are not in a regular manner by God’s greatness. To regulate the growth of teeth Dentist make use of orthodontic wire made of various types of alloys such as SS 18/8, Ni-Cr, SS 316, Thermoactive super elastic alloy, Gold 18 K, Gold 20 K etc., After having clipped with orthodontic wires people take many food items, tablets, juice etc., orally. Apart from saliva, these food items, may corrode the orthodontic wires. The consequence of glow discharge nitriding on the corrosion resistance of stainless steel orthodontic arches in artificial saliva solution has been studied by Kamiński et al [1] More research papers have been available in this regard [1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24].

Methods
Results
Conclusion