Abstract

Pelvic organ prolapse is a major burden for the public health system, affecting up to 30% of all women. One mesh kit has been introduced for pelvic organ prolapse surgery that can be inserted via a single anterior incision with the mesh arms driven through the sacrospinous ligament in a tension-free manner. The aim of this study was to describe the medium-term results of this vaginal mesh kit procedure for the combined treatment of the anterior vaginal wall and vault prolapse. This is a longitudinal case series of patients undergoing an anterior mesh operation between 2009 and 2013. All patients presenting with symptomatic stage II prolapse or higher were included when a minimum follow-up of 12months was achieved. A structured interview and clinical examination were performed pre- and postoperatively. One hundred and eighteen consecutive patients were operated with the Uphold® system during the study period. Three patients did not complete the 12-month follow-up and were excluded from the analysis, leaving 115 patients. Anatomical success at a mean follow-up of 23months was 93%, with a patient satisfaction rate of 95%. Four patients (8%) experienced de novo dyspareunia related to the mesh. The reoperation rate for mesh-related complications was 3.4%; no patients were re-operated for POP recurrence. The subjective and objective cure rates were high and the mesh-related re-operation rate was 3% in the medium term, suggesting that this surgical technique may be an option for women requiring anterior and apical prolapse repair.