Abstract

A novel application of retaining wall anchors as heat exchangers is proposed as an alternative or complement to pile geothermal exchangers. A fullscale in-situ study using anchors and piles was performed. Thermal response tests (TRT) were carried out in both types of systems. The installation process of the heat exchanger anchor is shown and results of the in-situ tests are compared in terms of their thermal parameters and performance. We demonstrate that the installation of required pipes is possible in the anchors with no mechanical interference during its installation and after anchor tensioning. The results show that the use of heat exchanger anchors is a valid alternative, with thermal performance similar to more common energy piles.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.