Abstract

This paper compares two calibration approaches to enhance the ability of hydrodynamic models to describe the performance of combined sewer overflow (CSO) structures. One approach is based on the duration of CSO events (monitored by low-cost sensors) and the other focuses on the overflow volume. Both were applied to the West-Graz catchment model to simulate the discharge from the CSO overflow channel under small, medium and large rain episodes. The methodology includes sensitivity analysis of the model parameters and automatic calibration through optimization. The results revealed that the calibration using the CSO duration led to results similar to those of the approach that used overflow volume, with less than 12% error differences between approaches for medium and large rain episodes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.