Abstract

The postirradiation response of CMOS transistors with 30-60-nm gate oxides is investigated as a function of radiation energy, total dose, dose rate, and annealing time. Measurements of threshold voltage, oxide-trapped charge, and interface traps are reported for times ranging from 10 ms to 4 months following LINAC, Co-60, Cs-137, and 10-keV X-ray irradiations. Exposure dose rates vary by 11 orders of magnitude: from 0.05 to 6*10/sup 9/ rad(SiO/sub 2/)/s. To within the +or-10% uncertainty in the overall dosimetry, no 'true' dose-rate effects on MOS device response are observed. Interface trap and oxide-trapped charge densities are linear with total dose. Preliminary recommendations are made for lot acceptance testing of hardened CMOS circuits and devices intended for use in space and strategic environments.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.