Abstract
To evaluate the safety of fiberoptic endoscopic evaluation of swallowing (FEES) and the reliability of both FEES and a videofluoroscopic swallowing study (VFSS) in identifying laryngeal penetration and tracheal aspiration in infants under 3 months old in the neonatal intensive care unit (NICU). Twenty-five infants at least 37 weeks postmenstrual age suspected of aspirating were assessed with FEES and VFSS. Complications, autonomic instability and vital signs before endoscope insertion and following FEES were documented. Blinded video recordings were coded by two reviewers to determine reliability. We found no major complications or significant differences between FEES prefeeding and postfeeding vital signs, including respiratory rate, heart rate or oxygen saturation. FEES interrater reliability was 80% for both penetration and aspiration, compared with 87 and 90%, respectively, for VFSS. FEES is safe and reliable in assessing laryngeal penetration and tracheal aspiration in NICU infants.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.