Abstract

Small (2 cm) peripheral lung lesions and ground glass opacities remain a difficult subset of lung lesions for the diagnosis and management of lung cancer. Surgical biopsy is more difficult for these lesions because intraoperative localization has to be made without the aid of direct visualization or manual palpation. Electromagnetic navigation bronchoscopy can be used in the operating room to identify a small peripheral lesion and marked using an injection of methylene blue, which can be seen on the visceral pleura of the lung. We present our initial experience using this technique. The sample was eight patients who had peripheral lesions with an average size of 19 mm. Surgical wedge biopsy was diagnostic in all cases, with an average procedure time of 28 minutes. There were no complications from this procedure. In conclusion, these data suggest that electromagnetic navigation bronchoscopy can be performed safely with high diagnostic accuracy by the operating thoracic surgeon, but further data are needed to establish its utility and safety.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.