Abstract

The paper proposes a contactless method for assessing the durability of the bond between glass fibre-reinforced polymer (GFRP) rebar and concrete under cyclic freeze-thaw conditions. The method is based on measuring the electric response to mechanical impact. Time- and frequency-related features of the measured signals are examined in a series of experiments with an increasing number of freeze-thaw cycles. The results of the theoretical and experimental studies of the electric response parameters under changing conditions of the rebar-concrete interface are presented. The experimental results demonstrate that the proposed method can be used to monitor the behavior of the rebar-concrete bond. The comparison of the proposed method with the acoustic method shows the former's higher sensitivity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.