Abstract

Although contrast agents would be beneficial, they are seldom used in four-dimensional (4D) flow magnetic resonance imaging (MRI) due to potential side effects and contraindications. To develop and evaluate a deep learning architecture to generate high blood-tissue contrast in noncontrast 4D flow MRI by emulating the use of an external contrast agent. Retrospective. Of 222 data sets, 141 were used for neural network (NN) training (69 with and 72 without contrast agent). Evaluation was performed on the remaining 81 noncontrast data sets. Gradient echo or echo-planar 4D flow MRI at 1.5 T and 3 T. A cyclic generative adversarial NN was trained to perform image translation between noncontrast and contrast data. Evaluation was performed quantitatively using contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), structural similarity index (SSIM), mean squared error (MSE) of edges, and Dice coefficient of segmentations. Three observers performed a qualitative assessment of blood-tissue contrast, noise, presence of artifacts, and image structure visualization. The Wilcoxon rank-sum test evaluated statistical significance. Kendall's concordance coefficient assessed interobserver agreement. Contrast in the regions of interest (ROIs) in the NN enhanced images increased by 88%, CNR increased by 63%, and SNR improved by 48% (all P < 0.001). The SSIM was 0.82± 0.01, and the MSE of edges was 0.09± 0.01 (range [0,1]). Segmentations based on the generated images resulted in a Dice similarity increase of 15.25%. The observers managed to differentiate between contrast MR images and our results; however, they preferred the NN enhanced images in 76.7% of cases. This percentage increased to 93.3% for phase-contrast MR angiograms created from the NN enhanced data. Visual grading scores were blood-tissue contrast=4.30± 0.74, noise=3.12± 0.98, and presence of artifacts=3.63± 0.76. Image structures within and without the ROIs resulted in scores of 3.42± 0.59 and 3.07± 0.71, respectively (P < 0.001). The proposed approach improves blood-tissue contrast in MR images and could be used to improve data quality, visualization, and postprocessing of cardiovascular 4D flow data. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 1.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.