Abstract
Thermal degradation of permafrost under road infrastructure regularly results in thaw settlement and severe structural damages. The present study discusses the results obtained by the implementation of a mitigation technique at a test section along the Alaska Highway near the Alaska-Yukon border (Beaver Creek). The objective of this study was to test possible way to slow down or prevent permafrost degradation under road embankment. Longitudinal air convection duct is a heat exchanger device based on fluid mechanics allowing for extraction of heat from the embankment by natural convective heat transfers during winter. Thermal analysis of the air temperature inside the ducts indicated that there was a strong thermal gradient between the inlets and the outlets, with air temperatures being 6 to 10˚C higher at the outlet than at in the inlet of the ducts. The cooling effect of the air convection duct system elevated the permafrost table by about 1 m over 3 years. This indicates that air convection ducts have a very good potential for heat extraction within road embankment and the underlying permafrost. This technique will likely find rapid applications in the engineering community aiming to develop adaptation strategies to climate warming for road infrastructure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.