Abstract
This study evaluated the optical method for measuring free total shrinkage using a Digital Single Lens Reflex (DSLR) camera. Eight composites were evaluated, conventional, bulk fill and low-shrinkage: Z100 (3M Oral Care), Gradia Direct Anterior (GC corporation), Spectra Smart (Dentsply), Filtek Z350 XT (3M Oral Care), Aura Bulk Fill (SDI), Vittra APS (FGM), Opus Bulk Fill APS (FGM), and Beautifil II LS (Shofu Inc.). The samples (6 mm diameter and 1.5 mm thick, n = 10) were placed on a polyvinylsiloxane impression material. An image of the uncured sample was captured using a DSLR camera with 105 mm macro lens and a ring flash. Samples were light cured with a 700 mW/cm2 LED light-cure unit for 40s. Post-polymerization images were captured at 2, 10 and 60 min. Projected circumferential areas of the specimens were drawn using the ImageJ software. Volumetric total shrinkage was calculated from the ratio of the areas obtained from pre- and post-curing. Results were analyzed using One-way ANOVA (α = 0.05) and Tukey test. Volumetric total shrinkage values were significantly different among the composite materials (p < .001). The volumetric shrinkage (%) mean and results of Tukey test at 60 min were: Z100: 3.45±0.30 (A); Gradia Direct Anterior: 3.00 ± 0.23 (B); Spectra Smart 2.89 ± 0.35 (B); Filtek Z350 XT: 2.65 ± 0.37 (BC); Aura Bulk Fill: 2.42 ± 0.25 (CD); Vittra APS: 2.14 ± 0.35 (DE); Opus Bulk Fill APS: 1.91 ± 0.24 (E); Beautifil II LS: 1.18 ± 0.16 (F). The optical method using a DSLR camera, was suitable for total shrinkage evaluation and will allow assessment of total shrinkage without the need for specialized equipment.
Highlights
The tested null hypothesis was that there would be no difference in volumetric total shrinkage values between conventional, bulk fill, and low-shrinkage composites evaluated by the Digital Single Lens Reflex (DSLR) optical method
Shrinkage values were significantly different among the composite materials tested
The lowest values found were for Beautifil II LS, followed by Opus Bulk Fill APS, which was statistically similar to Vittra APS (p = 0.652)
Summary
A simplified optical method for evaluating total shrinkage in restorative composites was introduced in 2015.17 Specimens of non-polymerized composite resins were positioned on a slick silicone base. The present study introduced and evaluated a new approach to optically measure free shrinkage of different brands of conventional, bulk fill, and low-shrinkage restorative composites using a DSLR camera with 105 mm macro lens and a ring flash.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.