Abstract

Despite recent repairs, a heated municipal swimming pool had major leaks. To determine the possible position of the leak or leaks, a full scale falling-head permeability test was performed. All the valves for circulating hot and cold water were closed for monitoring the variation with time of the water level in the pool. The velocity graph, which represents the conservation equation in variable-head tests, helped to determine the positions of leaks. Subsequent excavations found broken pipes and connections, their failure being related to high differential settlement caused by poor compaction of pipe foundations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.