Abstract

The investigation of leachate leakage at numerous landfill sites is urgently needed. This study presents an exploration of environmental tracing methods using δ2H and δ13C-difference in dissolved carbon (δ13CDIC-DOC) to localize leachate leak points at landfill sites. δ2H, δ13CDIC, δ13CDOC, δ18O, and an array of physicochemical indices (e.g., total dissolved solids, temperature, and oxidation reduction potential) were monitored in both leachate and groundwater from different zones of a landfill site in China during the year of 2021–2023. Moreover, data for these parameters (i.e., the isotopic composition and physicochemical indices) from twelve published landfill cases were also collected, and these groundwater/leachate data points were located within 1 km away from the landfill boundary. Then statistical analyses, such as Pearson correlation analysis and redundancy analysis (RDA), were performed using both the detected and collected parameters at landfill sites. Consequently, the intensity of interaction between leachate and background groundwater was found to significantly control the isotopic fractionation features of hydrogen and carbon, and both the content of major contamination indicators (total dissolved solids, chemical oxygen demand, and ammoniacal nitrogen) and the oxidation reduction potential were the key impact factors. Accordingly, the water type used to indicate leachate leakage points was determined to be leachate that significantly interacted with the background groundwater or precipitation (LBGP). δ2H showed a perfect linear correlation (0.81 ≤ r2 < 1.0) with δ13CDIC-DOC in leachate under highly anaerobic landfill conditions, and the δ2H &δ13CDIC-DOC combinations in the LBGP were significantly different from those in the other water types. For groundwater with total dissolved solids lower than 1400 mg/L at landfill sites, a strong positive linear correlation (r = 0.83) was revealed between δ13CDIC and δ13CDOC. Based on these insights, δ2H versus δ13CDIC-DOC plots and RDA using δ2H and δ13CDIC-DOC as response variables were proposed to localize leak points at both lined landfills and leachate facilities. These findings further understanding of the isotopic fractionation features of hydrogen, carbon, and oxygen and provide novel environmental tracer methods for investigating leachate leak points at MSW landfill sites.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.