Abstract
Explantation of a dislocated capsular tension ring (CTR) from the vitreous cavity can be challenging, typically requiring a bimanual hand-shake technique or cutting the CTR into segments. We present three cases of dislocated intraocular lens (IOL)-CTR-capsule complexes in which CTRs were explanted efficiently and safely by using a CTR inserter (CTR-I) through a clear corneal incision. Retrospective case series. Capsular tension rings were successfully explanted by freeing the eyelet of the CTR from the capsule, engaging it with the CTR-I hook and retracting the CTR into the device's shaft while maintaining the entire IOL-CTR-capsule complex in a safe position behind the iris plane. No complications of the procedure were observed in all three cases. All patients had subsequent uneventful IOL exchange through sutureless scleral fixation during the same surgery. The CTR inserter provides a simple and efficient approach to CTR removal from IOL-CTR-capsule complexes dislocated into the vitreous cavity. Greater awareness of this technique among providers is needed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.