Abstract

BackgroundPatient safety during anesthesia is crucially dependent on the monitoring of vital signs. However, the values obtained must also be perceived and correctly classified by the attending care providers. To facilitate these processes, we developed Visual-Patient-avatar, an animated virtual model of the monitored patient, which innovatively presents numerical and waveform data following user-centered design principles. After a high-fidelity simulation study, we analyzed the participants’ perceptions of 3 different monitor modalities, including this newly introduced technique.ObjectiveThe aim of this study was to collect and evaluate participants’ opinions and experiences regarding 3 different monitor modalities, which are Visual-Patient-avatar, Split Screen (avatar and Conventional monitor alongside each other), and Conventional monitor after using them during simulated critical anesthetic events.MethodsThis study was a researcher-initiated, single-center, semiquantitative study. We asked 92 care providers right after finishing 3 simulated emergency scenarios about their positive and negative opinions concerning the different monitor modalities. We processed the field notes obtained and derived the main categories and corresponding subthemes following qualitative research methods.ResultsWe gained a total of 307 statements. Through a context-based analysis, we identified the 3 main categories of “Visual-Patient-avatar,” “Split Screen,” and “Conventional monitor” and divided them into 11 positive and negative subthemes. We achieved substantial interrater reliability in assigning the statements to 1 of the topics. Most of the statements concerned the design and usability features of the avatar or the Split Screen mode.ConclusionsThis study semiquantitatively reviewed the clinical applicability of the Visual-Patient-avatar technique in a high-fidelity simulation study and revealed the strengths and limitations of the avatar only and Split Screen modality. In addition to valuable suggestions for improving the design, the requirement for training prior to clinical implementation was emphasized. The responses to the Split Screen suggest that this symbiotic modality generates better situation awareness in combination with numerical data and accurate curves. As a subsequent development step, a real-life introduction study is planned, where we will test the avatar in Split Screen mode under actual clinical conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.