Abstract

Renal artery stenosis is a common cause of secondary hypertension and ischemic nephropathy. Percutaneous angioplasty and stent placement has allowed select patients with renal artery stenosis to use fewer antihypertensive agents and improve or stabilize renal function. The associations of baseline systolic, diastolic, and pulse pressures (PPs) with outcomes of blood pressure (BP) and renal function were examined in 243 patients who underwent renal angioplasty and stent placement. The average PP before the procedure in patients with improvements or stabilizations in renal function was 53 +/- 20 mm Hg, compared to 107 +/- 18 mm Hg (p <0.05) in those with poorer outcomes. The average PPs before procedure were 47 +/- 15 mm Hg in those with improvements in BP, 82 +/- 10 mm Hg in those with stabilizations of BP, and 111 +/- 14 mm Hg in those with worsening BP. All findings were statistically significant (p <0.05). In conclusion, wide PP may reflect more advanced vascular stiffness and renal disease distinguishing patients less likely to benefit from revascularization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.