Abstract

Diverse and contradictory approaches have been suggested for the management of non-palpable thyroid nodules. The aim of our study was to evaluate the indications and limits of ultrasound-guided fine-needle aspiration cytology (US-FNAC) in non-palpable infracentimetric thyroid nodules. From September 2003 to December 2004 we observed 325 patients with non-palpable thyroid nodules. We divided our series into three groups according to the diameter of the lesion in order to verify the effectiveness of US-FNAC for lesions of less than 1 cm. We assessed the cases with satisfactory and unsatisfactory results in the three groups into which the sample was divided (4 mm to 1 cm; 10.1 mm to 15 mm, and 15.1 mm to 25.5 mm). Our statistical analysis by means of the z-test showed there was no significant (5%) difference in the percentage distribution of the unsatisfactory results in the three groups. Fine-needle cytology appears to be a useful diagnostic tool also for nodules of less than one cm because the percentage of unsatisfactory results is not related to the size of the nodule.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.